  euro cassetes powering progress ? www.powerbox.com.au doc. no. pbc9 rev.c 28-4-11 features ? dc input 10 - 380 v ? ac input 1 or 3-phase, 47 - 400 hz ? dc output 5-400v ? continuous short circuit protection ? overvoltage protection with auto restart ? industrial grade components ? compact and robust design C1500 series 400-600 watts ac/dc-dc/dc-battery chargers single output 400 w 500 w 600 w input vdc output vdc 10 ?16 vdc output amps 18 ? 36 vdc output amps 36 ? 75 vdc 45 ? 90 vdc 80 ?160 vdc 160 ? 320 vdc 320 ? 380 vdc output amps adj. range c 1500 40 c 1520 60 c 1530 c 1540 c 1550 c 1570 c 1580 z 80 5 4.5 ? 5.5 c 1501 25 c 1521 38 c 1531 c 1541 c 1551 c 1571 c 1581 z 50 9 8 ? 10 c 1502 24 c 1522 33 c 1532 c 1542 c 1552 c 1572 c 1582 z 42 12 11 ? 13 c 1503 20 c 1523 25 c 1533 c 1543 c 1553 c 1573 c 1583 z 34 15 14 ? 16 c 1504 15 c 1524 18 c 1534 c 1544 c 1554 c 1574 c 1584 z 23 24 23 ? 26 c 1505 13 c 1525 15 c 1535 c 1545 c 1555 c 1575 c 1585 z 20 28 26 ? 30 c 1509 7 c 1529 8 c 1539 c 1549 c 1559 c 1579 c 1589 z 11 48 45 ? 55 c 1506 5.5 c 1526 6.5 c 1536 c 1546 c 1556 c 1576 c 1586 z 9 60 58 ? 68 c 1507 3 c 1527 3.3 c 1537 c 1547 c 1557 c 1577 c 1587 z 4.5 110 100 ? 130 c 1507 j 2 c 1527 j 2.5 c 1537 j c 1547 j c 1557 j c 1577 j c 1587 zj 3 200 190 ? 200 c 1508 1.4 c 1528 1.6 c 1538 c 1548 c 1558 c 1578 c 1588 z 2.4 220 200 ? 250 c 1508 j 1 c 1528 j 1.3 c 1538 j c 1548 j c 1558 j c 1578 j c 1588 zj 1.5 400 380 ? 400 dc/dc converters ac/dc power supplies battery chargers 600 w input vac, 1-phase input vac, 3-phase output amps output vdc 115 20% 230 + 15% ? 20% 115 20% 230 + 15% ? 20% 3x200 + 15% ? 20% nom. battery voltage range b 1561 b 1581 b 1591 b 1561 v 34 12 12 ? 16 b 1562 b 1582 b 1592 b 1562 v 18 24 24 ? 32 b 1564 b 1584 b 1594 b 1564 v 9 48 48 ? 64 b 1566 b 1586 b 1596 b 1566 v 7.5 60 60 ? 80 b 1567 b 1587 b 1597 b 1567 v 4 110 110 ? 145 b 1568 b 1588 b 1598 b 1568 v 2 220 220 ? 290 600 w input vac, 1-phase input vac, 3-phase output amps output vdc 115 20% 230 + 15% ? 20% 115 20% 230 + 15% ? 20% 3x200 + 15% ? 20% adj. range c 1560 c 1580 c 1590 c 1560 v 80 5 4.5 ? 5.5 c 1561 c 1581 c 1591 c 1561 v 50 9 8 ? 10 c 1562 c 1582 c 1592 c 1562 v 42 12 11 ? 13 c 1563 c 1583 c 1593 c 1563 v 34 15 14 ? 16 c 1564 c 1584 c 1594 c 1564 v 23 24 23 ? 26 c 1565 c 1585 c 1595 c 1565 v 20 28 26 ? 30 c 1569 c 1589 c 1599 c 1569 v 11 48 45 ? 55 c 1566 c 1586 c 1596 c 1566 v 9 60 58 ? 68 c 1567 c 1587 c 1597 c 1567 v 4.5 110 100 ? 130 c 1567 j c 1587 j c 1597 j c 1567 vj 3 200 190 ? 200 c 1568 c 1588 c 1598 c 1568 v 2.4 220 200 ? 250 c 1568 j c 1588 j c 1598 j c 1568 vj 1.5 400 380 ? 400
euro cassetes powering progress ? www.powerbox.com.au doc. no. pbc9 rev.c 28-4-11 euro series euro option specifications options input option ?i? (inrush current limiting): a thermistor is connected in series with the input lines which changes its resistance from high to low when it gets hot. it does not reduce the current surge if the input power is interrupted for a short period of time not allowing the thermistor to cool down. thermistors are fitted as standard to all mains input models except for 1-phase input of models > 2.5kw. thermistors are available up to 45a. for higher input current an electronic inrush current limitation can be offered. option ? ie ? electronic inrush current limiting an electronic circuit limits the inrush current. option ? sd ? (series diode): a series diode protects the module against input voltage of wrong polarity (additional power losses). option ? ad ? (anti-parallel diode): to avoid the power losses of a series diode a diode is provided with opposite polarity in parallel to the input blowing an internal or external fuse if the module is connected to a supply with wrong polarity. option ? au ? (auto-ranging) for standard dual ac input models the range of 115/230vac is to be selected by connecting the input line to different pins on the connector. with auto-ranging the unit senses the input voltage and provides automatically the correct connection. option ? p ? (power fail): a signal (logic or relay) is given if the input voltage (ac or dc) drops below the specified limit. in ac input units we sense the rectified input voltage so that a power fail alarm will not be triggered if at light loads mains power returns before the input capacitors are substantially discharged. option ? r ? (relay): a relay instead of a logic signal is provided for failure indication. output option ? dd ? (decoupling diode): for redundant operation the outputs of two or more units are paralleled behind de-coupling diodes so that an internal fault of one module does not affect the operation of the others. these diodes cause power losses. option ? cs ? (active current sharing): an additional control circuit provides active current sharing via an interconnecting wire between converters that operate in parallel. active current sharing should be used for multi-output units operating in parallel. option ? csi ? (current sharing interrupt): option ?csi? will effect the removal of the ?cs? signal. should there be an instance where a unit is not supplying the load, then the effect of its ?cs? signal is removed, and the load voltage is unaffected by this condition. option ? h1 ? (inhibit): a te rminal connected to the negative input line also shuts off the converter. this can also be used in conjunction with a thermal trip which shuts the unit down. option ? h2 ? (inhibit): operation of the unit is inhibited if a voltage signal (5v/10ma) is applied in reference to the negative line of the (main) output. option ? rco ? (reducing current limiting at over temperature) a circuit reduces the current limiting level at higher temperature (to be specified). option ? d ? (dc-ok, one output): a logic signal is given if the output voltage (main output in multi-output systems) is below the specified limit. option ? m ? (dc-ok, all outputs): in multi-output systems a logic signal is provided if the voltage of any output is below the specified limit. option ? ac ? (ac ok) a logic signal connected to relay contacts is given if the output voltage of an inverter is below the specified limit. programming series 200-5800, 6600 of output voltage from 0 to 100% by external signal, 0-10vdc eu1 by external signal, 4-20ma eu2 by 270 potentiometer eu3 by 10 turn potentiometer eu4 of output current from 0 to 100% by external signal, 0-10vdc ei1 by external signal, 4-20ma ei2 by 270 potentiometer ei3 by 10 turn potentiometer ei4 isolating amplifier for programming iso programming via interface rs232 or ieee488 monitoring series 200-5800, 6600 of output voltage from 0 to 100% by external signal, 0-10vdc mu1 by external signal, 4-20ma mu2 of output current from 0 to 100% by external signal, 0-10vdc mi1 by external signal, 4-20ma mi2 isolating amplifier for programming iso programming via interface rs232 or ieee488 charger programming (all series) temperature compensated charging voltage(sensor not included) tc temperature sensor not interchangeable due to fixed resistor values ts1 interchangeable, ic controlled ts2 automatic selection of charging characteristic (float / equalize charge) with timer ch1 additionally: manual selection of charging characteristic ch2 additionally: boost charge operation (manually activated with time delayed return to normal operation) ch3 option ? y ? (sys-reset): this logic signal is a combination of power fail and dc-ok as specified for vme systems. option ? r ? (relay): a relay instead of a logic signal is provided for failure indication.` programming & monitoring
euro cassetes doc. no. pbc9 rev.c 28-4-11 environment option ? t ? (tropical protection):the unit is given additional protection by a heavy coat of varnish on the printed circuit board(s) and components. option ? c ? (extended temperature range):the circuit is designed and tested for operation at an ambient temperature as low as ?40 c. option ? ms ? (increased mechanical strength): screws are secured by locktite and heavy components are fastened by ties and/or glue. modules with the ?ms? option meet the standard en61373 regarding shock and vibration. mechanics standard mounting ? eurocassette ? pluggable module for 19? sub-racks 84te option ? w ? (wall mounting): module is screwed against a mounting plate for installation in a cabinet. the load connections are typically a terminal block. option ? cha ? (chassis mount) module is designed for installation to a structure or within cabinet. screw type connectors are supplied with the module. option ? din ? (din rail mount) module is designed for din rail mounting to a structure or within cabinet. screw type connectors are supplied with the module. programming / monitoring- series 6400 programming of output voltage and current from 0-100% including isolation by external signal, 0-10vdc e1 by external signal, 4-20ma e2 programming of output voltage from 0-100% by 270 potentiometer eu3 by 10 turn potentiometer eu4 programming of output current from 0-100% by 270 potentiometer ei3 by 10 turn potentiometer ei4 monitoring of output voltage and current from 0-100% including isolation by external signal, 0-10vdc m1 by external signal, 4-20ma m2 remote on/off programming and monitoring of output voltage and current from 0-100% including isolation by external signal, 0-10vdc em1 by external signal, 4-20ma em2 via rs232 and ieee488 em3 improved tolerance between reference (external signal) and measured value / between measured value and displayed signal: voltage 0.2% and current 0.5%. tol euro series euro option specifications


▲Up To Search▲   

 
Price & Availability of C1500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X